Table 1 gives the BWEA Reference Annual Energy for the Aircon 10S. Table 2 shows the AEP estimations for hub height integer annual average wind speeds from 4m/s, up to the maximum wind speed for the turbine class II at sea level air density.

 

BWEA Reference Annual Energy [kWh]: 17488

 

Estimated Annual Energy Production

Reference Air Density: 1.225kg/m³
Cut Out Wind Speed: No cut out wind speed but extrapolation taken up to 25m/s


extrapolated measured
Wind- Rayleigh distribution
Annual production
Uncertainty of
the measure

Annual production
Uncertainty of
the measure
(standard deviation) (standard deviation)
[m/s] [kWh] [kWh] % [kWh] [kWh] %
4 9065 880 9.7 9065 880 9.7
5 17488 1238 7.1 17488 1238 7.1
6 26714 1466 5.5 26714 1466 5.5
7 35599 1571 4.4 35599 1571 4.4
8 43549 1596 3.7 43549 1593 3.7
9 50307 1576 3.1 50307 1567 3.1
10 55731 1534 2.8 55731 1514 2.8
11 59788 1482 2.5 59788 1446 2.5